Can be Modbus connected to either our WTA036 or WTA060 but also on ZMX-TPHP third party equipment control panel
Y, O, G and W thermostat inputs for each zone
24V digital outputs for air dampers actuators
ZMX-TPHP
Third party heat pump and HVAC equipment’s main control panel
24V inputs and outputs
Humidifier and HRV inputs
G1 G2 and W outputs for ventilation cabinet or electric furnace
24V output for auxiliary or emergency heat
Y and O/B outputs for third party heat pump, W input for heat pump defrost cycle
Must be Modbus connected to 1-4 ZMX-CM-24V zoning panels
ZMX-GEO-M
Main Control Panel for ZMX-GEO System – Radiant floor and air for each zone
Controls HVAC and geothermal equipments as per each zone demands for radiant floor heat and air
Modbus connected to as much as 4 ZMX-GEO-Z4 zoning panels
Can be configured for many applications and system architecture
USB interface with Labview based monitoring application
ZMX-GEO-Z4
ZMX-GEO System 4 zones zoning panel – Radiant floor and air for each zone
Conventional or heat pump configurable thermostat inputs for each zone
Air damper and water valve outputs for each zone
Up to 16 zones by connecting 4 ZMX-GEO-Z4 to the Modbus network
Radiant floor in first stage, air in second stage
Many possible configurations for each zone
ZMX-WTW-HAC
Simultaneous heat and cool conversion panel for WTW060
When connected to this panel, the WTW060 unit turns into a unit that heat on the load side and cools on the source side. The WTW060 unit acts as two buffer tanks (Hot and Cold) without tanks
Up to 4 WTW060 units can be connected to form a single 240 000btu/h system
Control of 2 modulating three way valves that will operate to keep the energy balance on each side by dumping energy to the well or extracting energy from the well
ZMX-OATS
Outdoor Air Temperature Sensor Module for WTA and WTW
When connected to a WTW or WTA unit, the unit's heat setpoints will vary with outdoor air temperature
Modbus connected to the unit’s network
Included sun-shield
ZMX-FLRTS
Radiant Floor Water Temperature Sensor Module
Must be connected to ZMX-GEO-M panel in order to limit the water temperature sent to radiant floors when ther is a very hot water demand on the heat pump (ex: domestic hot water)
When connected to ZMX-GEO-M panel, this last one will modulate a three way bypass valve in order to limit the temperature of the water sent to the radiant floors distribution system
ZMX-DHWTS
Domestic Hot Water Temperature Sensor Module
Acts as a thermostat for the domestic hot water preheat tank