Designed and made in QuebecEnergy from the ground, innovation from here
Geothermal range · Water-to-air

Energy from the ground.
Comfort in the air.

A variable-capacity heat pump to heat and cool your building through a forced-air system.

Water-to-air geothermal · 3 T variable · 36,000 BTU/h
Calorek WTA unit
Range visualWater-to-air unit
The model that fits you

3 tons.
Power that adapts.

The capacity is chosen from a heat-load calculation, not from floor area alone.

Proposed capacity3 tons36,000 BTU/h
OperationVariable
DistributionForced air

Forced-air distribution

Heating and cooling travel through your ducts.

Matched ventilation

The airflow follows what the system needs.

Zoning

Compatible controls set the comfort room by room.

New build or renovation

New house or existing system: each integration is reviewed case by case.

Performance, dimensions and options must be checked in the model’s own specification sheet. The visual shows the product family.

Variable-capacity technology

Just the energy
you need.

The variable-speed compressor adjusts the heat pump’s output to the demand. Comfort stays steadier as the building’s needs change.

The ground loop, the controls and the distribution are sized together, so the system delivers its full efficiency.

How it works

From the ground to your home.

A loop in the ground. Comfortable air in every room.

Heating or cooling · Schematic
To the ground: cooled liquidBack: liquid warmed by the groundWarm air to the roomsReturn air
Frost lineUpstairsGround floorBasementCalorekHeat pump1Draw energy from the groundThe loop’s liquid warms upin contact with the ground.2Transfer the heatThe compressor raises the temperature.The ground circuit stays separate.3DistributeWarm air travels through the ductsto every room.
Vertical loop (borehole), horizontal (trench below the frost line) or hybrid (both). Equipment, routes and proportions simplified; every project is laid out differently.
1Capture

The underground loop picks up heat from the ground.

2Transfer

The heat pump transfers that energy to the indoor circuit.

3Distribute

The ducts carry heated air to the rooms.

And in summer?

The cycle reverses: the heat pump removes heat from the indoor air and transfers it to the ground. The same ducts deliver the cooled air.

At a glance

Technical specifications.

Water-to-air geothermal · 3 tons, variable capacity
Range capacity3 tons
Nominal equivalent*36,000 BTU/h
CompressorVariable speed, inverter
Thermal energy sourceGround loop
Distribution in the buildingAir · duct network
FunctionsHeating and cooling

* Capacity class conversion: 1 ton = 12,000 BTU/h. This is not the unit’s measured output, which varies with operating conditions and must be confirmed in the model’s sheet.

COP/EER performance, power supply, dimensions and installation instructions: see the documents for your unit.